Page 69 - LIT-18626-11-76
P. 69

UF3Y11E0.book  Page 64  Tuesday, May 23, 2017  9:23 AM



                                                                Pre-operation checks

                        flood the engine compartment and cause  EJU40146
                                                              Post-launch checks
                        the watercraft to submerge. [ECJ00363]
                                                              Perform the post-launch checks in the pre-
                                                              operation checklist while the watercraft is in
                                                              the water and the engine is running.
                                                              To perform the post-launch checks:
                                                              (1) Launch the watercraft. (See page 67 for
                                                                 information on launching the watercraft.)
                                                              (2) Perform the checks and make sure that
                                                                 there are no malfunctioning items or oth-
                                   2                             er problems.
                                                              EJU40553
                                   1                          Cooling water pilot outlet check
                          1 Stern drain plug                  Make sure that water is discharged from the
                          2 O-ring
                                                              cooling water pilot outlet while the engine is
                        Securely install the stern drain plugs by tight-  running. (See page 32 for information on the
                        ening them until they stop.           cooling water pilot outlet.)








                                       1




                          1 Stern drain plug                  EJU32715
                                                              Multifunction information center check
                        EJU44640
                        Hood check                            Make sure that the multifunction information
                        Close the hood, hook the hood latches, and  center operates properly. (See page 38 for in-
                        check that the hood is securely closed.  formation on proper operation of the multi-
                                                              function information center.)






                                                     1





                          1 Hood latch


                                                                                               64
   64   65   66   67   68   69   70   71   72   73   74