Page 99 - LIT-18626-12-10
P. 99

UF3V10E0.book  Page 94  Thursday, August 23, 2018  9:17 AM



                                                                       Care and storage

                        Internal: Drink large quantities of water or  Checking the electrolyte level
                        milk. Follow with milk of magnesia, beaten  Make sure  that the electrolyte level is be-
                        egg, or vegetable oil. Call a physician im-  tween the maximum  and  minimum level
                        mediately.                            marks.
                        Eyes: Flush with water for 15 minutes and  If the electrolyte level is low, add distilled wa-
                        get prompt medical attention.         ter to raise it to the specified level. NOTICE:
                        Batteries produce explosive gases. Keep  Use only distilled water for  replenishing
                        sparks, flames, cigarettes, etc., well away.  the battery, otherwise battery life could be
                        If using or charging the battery in an en-  shortened. [ECJ00242]
                        closed space, make sure that it is well
                        ventilated. Always shield your eyes when
                        working near batteries.
                        Keep out of the reach of children.

                        To remove the battery:
                        (1) Disconnect the negative (–) battery lead.
                        (2) Disconnect the positive (+) battery lead.
                        (3) Disconnect the breather hose.
                        (4) Unhook the battery bands, and then re-
                            move the battery from the watercraft.  1 Maximum level mark
                                                               2 Minimum level mark
                         1  2       3
                                                              If distilled water was added, check the bat-
                                                              tery voltage.
                                                              It is recommended to have a Yamaha dealer
                                                              check the battery voltage and charge the bat-
                                    4                         tery. If you  charge the battery  yourself, be
                                                              sure to read and follow the instructions pro-
                                                              vided with the battery tester and charger you
                                                              use. NOTICE: Do not attempt to charge a
                                                              battery hastily. Battery life could be short-
                          1 Negative (–) battery terminal: Black lead
                                                              ened. [ECJ00252]
                          2 Battery band
                          3 Positive (+) battery terminal: Red lead
                          4 Breather hose
                        Checking the battery
                         Make sure that the battery case is not dam-
                          aged.
                         Make  sure that the  battery terminals are
                          not corroded or damaged.
                         Make sure that the breather  hose  is not
                          clogged or damaged.




                                                                                               94